Set details
Select the frame type first, and then open the "Set details"
dialog.
In this dialog to define the individual parameters for the fields of the selected frame.
Enable/ Field name/ Condition ← Set details
This table lists the field numbers and names in the selected frame together with a sum-
mary of the user settings of checking conditions for each field and a checkbox to
enable the checking.
Select a field in the table to specify the checking conditions for this field in the
"Data"
,
"BitState" and/or "Index" dialog (whichever applies). The condition is only applied, and
the "Condition Summary" is only shown in the table, if "Enable" is checked.
For an overview of frames and fields, see "Frame packet types" on page 862.
Remote command:
TRIGger<m>:USBPd:FIENable on page 2223
TRIGger<m>:USBPd:FRAMe<n>:FLD<o>:ENABle on page 2223
Error > Enable /Item
The table lists the error types you can trigger on: "CRC Error", "Length Error", "4b5b
Error". Enable any error that you want to trigger on in the "OR" column.
Remote command:
TRIGger<m>:USBPd:ERENable on page 2222
TRIGger<m>:USBPd:ERRor<n>:ENABle on page 2222
Data
Sets the data to be triggered on. The trigger data setup consists of a comparison con-
dition and one or two data patterns.
"Condition"
Sets the comparison condition to a specific value or a range.
"Min"
Specifies the value or sets the start value of a range.
USBPD (option R&S R