EasyManua.ls Logo

R&S RTO6 - Page 889

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol analysis
R&S
®
RTO6
889User Manual 1801.6687.02 ─ 05
"Data Min/Data"
Defines the bit pattern of the data value pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
T
o enter the pattern in other formats use the bit pattern editor
, see
Chapter 13.1.7, "Bit pattern editor", on page 493.
"Data Max"
The second data value pattern is required to specify a range with
conditions "In range" and "Out of range".
Remote command:
For "Type">"HS Data":
SEARch:
TRIGger:DPHY:DATA:CONDition on page 2262
SEARch:TRIGger:DPHY:DATA:MAX on page 2262
SEARch:TRIGger:DPHY:DATA:MIN on page 2262
For "Type">"LP Escape Mode":
SEARch:TRIGger:DPHY:ESDTa:CONDition on page 2266
SEARch:TRIGger:DPHY:ESDTa:MAX on page 2266
SEARch:TRIGger:DPHY:ESDTa:MIN on page 2266
Data Index
Data index sets the range within this series of the data value to be searched for. The
data index setup consists of the condition and one or two data index values.
"Condition"
Defines the operator to set a specific data ("Equal") or a data range.
"Index Min/Index"
Defines the minimum index.
"Index Max"
The second index pattern is required to specify a range with condi-
tions "In range"
.
Remote command:
For "Type">"HS Data":
SEARch:
TRIGger:DPHY:DIDX:CONDition on page 2263
SEARch:TRIGger:DPHY:DIDX:MAX on page 2263
SEARch:TRIGger:DPHY:DIDX:MIN on page 2263
For "Type">"LP Escape Mode":
SEARch:TRIGger:DPHY:ESINdex:CONDition on page 2267
SEARch:TRIGger:DPHY:ESINdex:MAX on page 2267
SEARch:TRIGger:DPHY:ESINdex:MIN on page 2267
Escape mode
Searches for an escape mode event. The escape mode setup consists of the condition
and one or two data patterns.
"Condition"
Defines the operator to set a specific word count ("Equal" or "Not
equal") or a word count range.
"Data Min/Data"
Defines the bit pattern of the data pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
T
o enter the pattern in other formats use the bit pattern editor
, see
Chapter 13.1.7, "Bit pattern editor", on page 493.
D-PHY (option R&S RT
O6-K580)

Table of Contents