Jitter analysis and clock data recovery
R&S
®
RTO6
1113User Manual 1801.6687.02 ─ 05
Source
Selects the source of the data stream.
Remote command:
CDR:SOFTware<m>:ESBRate:SOURce
on page 2511
Serial standard
For some serial standards, the bit rate and bandwidth are known to the instrument.
Select the standard, and the "Nominal bit rate" and bandwidth settings are set auto-
matically, no estimation is required.
Remote command:
CDR:SOFTware<m>:SERStandard on page 2510
Data edges
Selects the edges of the data stream that are used for the clock recovery.
"Either": Both positive and negative edges are used
"Positive / Negative": Only one edge direction is used. Use one of these settings if
the other edge might deliver unreliable results.
Remote command:
CDR:SOFTware<m>:ESLope on page 2512
Algorithm
Sets the software algorithm that is used for clock data recovery.
Clock data recovery