Remote control commands
R&S
®
RTO6
2512User Manual 1801.6687.02 ─ 05
Suffix:
<m>
.
1..2
Number of the software CDR setup
Parameters:
<BitrateEstimation> ON | OFF
*RST: OFF
Usage: Asynchronous command
CDR:SOFTware<m>:BITRate <Bitrate>
Sets the quiescent frequency of the PLL. It corresponds to the data rate of the data
stream from which the clock is to be recovered.
Suffix:
<m>
.
1..2
Number of the software CDR setup
Parameters:
<Bitrate> Range: 100 to max {5 Gbps, <available instrument band-
width}
Increment: 10
*RST: 1E+9
Default unit: bps
Usage: Asynchronous command
CDR:SOFTware<m>:ESLope <Edge>
Selects the edges of the data stream that are used for the clock recovery.
"Either": Both positive and negative edges are used
"Positive / Negative": Only one edge direction is used. Use one of these settings if
the other edge might deliver unreliable results.
Suffix:
<m>
.
1..2
Number of the software CDR setup
Parameters:
<Edge> POSitive | NEGative |
EITHer
*RST: EITHer
Usage: Asynchronous command
CDR:SOFTware<m>:SYNC <InitialSync>
Defines the phase reference for the first clock edge.