EasyManua.ls Logo

R&S RTO6 - Page 1438

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTO6
1438User Manual 1801.6687.02 ─ 05
LAYout:ZOOM:VERTical:MODE.....................................................................................
1442
LA
Yout:ZOOM:VERTical:ABSolute:POSition................................................................... 1443
LAYout:ZOOM:VERTical:ABSolute:SPAN....................................................................... 1443
LAYout:ZOOM:VERTical:ABSolute:STARt.......................................................................1444
LAYout:ZOOM:VERTical:ABSolute:STOP....................................................................... 1444
LAYout:ZOOM:VERTical:RELative:POSition....................................................................1444
LAYout:ZOOM:VERTical:RELative:SPAN........................................................................1445
LAYout:ZOOM:VERTical:RELative:STARt....................................................................... 1445
LAYout:ZOOM:VERTical:RELative:STOP........................................................................1445
LAYout:ZOOM:REMove................................................................................................ 1446
LAYout:ZOOM:ADD <NodeName>, <ParentType>, <InsertBefore>, <XStart>,
<XStop>, <YStart>, <YStop>, <NewZoomName>
Adds a new zoom diagram based on the specified waveform.
For numerical values, the input of a unit is not supported for this command.
Setting parameters:
<NodeName> String with the name of diagram to be zoomed
<ParentType> VERTical, OFF
The new zoom diagram is displayed below the original one.
<InsertBefore> OFF
Position of the zoom diagram, depending on ParentType
<XStart> Defines the x-value at the beginning of the zoom area.
<XStop> Defines the x-value at the end of the zoom area.
<YStart> Defines the y-value at the beginning of the zoom area.
<YStop> Defines the y-value at the end of the zoom area.
<NewZoomName> String with the name of the new zoom diagram.
Example:
LAYout:ZOOM:ADD 'Diagram1', VERT, OFF, -10e-9,
20e-9, -0.1,
0.05, 'MyZoom1'
Creates the zoom diagram 'MyZoom1' for 'Diagram1'.
Example: See
Chapter 24.3.1.2, "Creating zoom diagrams", on page 1261
Usage: Setting only
Asynchronous command
LAYout:ZOOM:ADDCoupled <ZoomName>, <XOffset>, <YOf
fset>,
<NewZoomName>
Creates a new zoom diagram based on the settings of an existing zoom area for the
same source.
For numerical values, the input of a unit is not supported for this command.
Parameters:
<NewZoomName> Defines the name of the new zoom diagram.
Waveform analysis

Table of Contents

Other manuals for R&S RTO6

Related product manuals