Remote control commands
R&S
®
RTO6
1653User Manual 1801.6687.02 ─ 05
Parameters:
<Stop> Range: -100E+24 to 100E+24
Increment: 0.01
*RST: 0.01
Default unit: s
Usage: Asynchronous command
EXPort:WAVeform:ZOOM <ZoomDiagram>
Sets the zoom area to be used for limited data export if EXPort:WAVeform:SCOPe is
set to
ZOOM.
Parameters:
<ZoomDiagram> Name of the diagram on which the zoom area is based.
Example: See "Exporting interleaved x/y data of a zoom to CSV file"
on page 1269
Usage: Asynchronous command
EXPort:WAVeform:CURSorset <Cursorset>
Sets the cursor set to be used for limited data export if EXPort:WAVeform:SCOPe is
set to CURSor.
Parameters:
<Cursorset> CURSOR1 | CURSor1 | CURSOR2 | CURSor2 | CURSOR3 |
CURSor3 | CURSOR4 | CURSor4
CURSOR1 = CURSor1, CURSOR2 = CURSor2, CURSOR3 =
CURSor3, CURSOR4 = CURSor4
Usage: Asynchronous command
EXPort:WAVeform:MEAS <MeasGate>
Sets the gate to be used for limited data export if EXPort:WAVeform:SCOPe
is set to
GATE.
Parameters:
<MeasGate> MEAS1 | MEAS2 | MEAS3 | MEAS4 | MEAS5 | MEAS6 |
MEAS7 | MEAS8
Measurement for which the gate is defined.
Example: See "Exporting raw data of a measurement gate to BIN file"
on page 1268
Usage: Asynchronous command
Data management