Remote control commands
R&S
®
RTO6
2203User Manual 1801.6687.02 ─ 05
<o> *
Parameters:
<IndexOperator> EQUal | INRange | RANGe
EQUal
This condition requires one endpoint value to be set using
TRIGger<m>:USBThree:
FRAMe<n>:FLD<o>:IMIN.
INRange | RANGe
This condition requires a range of endpoint values to be set
using TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:IMIN and
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:IMAX.
*RST: INRange
TRIGger<m>:USBThree:IMIN <Frame>, <Field>, <Data>
TRIGger<m>:USBThree:FRAMe<n>:FLD<o>:
IMIN <IndexMin>
Specifies the index, or sets the start value of an index range.
Suffix:
<m>
.
1..3
<n> *
Specifies the field number within the frame.
<o> *
Parameters:
<IndexMin> Specifies the index value or index start value within the field.
The index range, increment and *RST values depend on the
field type.
TRIGger<m>:USBThree:IMAX <Frame>, <Field>, <Data>
TRIGger<m>:USBThree:FRAMe<n>:
FLD<o>:
IMAX <IndexMax>
Sets the end value of an index range if TRIGger<m>:USBThree:FRAMe<n>:
FLD<o>:IOPerator is set to INRange or RANGe.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
<n> *
Specifies the field number within the frame.
<o> *
Parameters:
<IndexMax>
Specifies the end value for the index range within the field.
The index range, increment and *RST values depend on the
field type.
Protocols