EasyManua.ls Logo

R&S RTO6 - Page 2455

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTO6
2455User Manual 1801.6687.02 ─ 05
Suffix:
<m>
.
1..2
Return values:
<NumSamples> Range: 0 to 128000000
Increment: 10
*RST: 0
Default unit: pts
Usage: Query only
WGENerator<m>:ARBGen:SELect <ScopeSignSrc>
Selects the oscilloscope source, from which the arbitrary signal is loaded, if
WGENerator<m>:ARBGen[:
SOURce] is set to SCOPe.
Suffix:
<m>
.
1..2
Parameters:
<ScopeSignSrc> NONE | C1W1 | C1W2 | C1W3 | C2W1 | C2W2 | C2W3 | C3W1 |
C3W2 | C3W3 | C4W1 | C4W2 | C4W3 | R1 |
R2 | R3 | R4 |
DIFF1 | DIFF2 | COMMON1 | COMMON2
*RST: NONE
WGENerator<m>:ARBGen:SRATe <SampleRate>
Sets the sample rate for the arbitrary waveform.
Suffix:
<m>
.
1..2
Parameters:
<SampleRate> Range: 1 to 250E+6
Increment: 10
*RST: 1E+6
Default unit: Sa/s
WGENerator<m>:ARBGen[:SOURce] <WaveformSource>
Sets the arbitrary waveform source.
Suffix:
<m>
.
1..2
Parameters:
<W
aveformSource> ARBitrary | SCOPe
ARBitrary
Enables you to load an existing arbitrary file.
SCOPe
Enables you to load a scope waveform.
Waveform generator (option R&S RT
O6-B6)