Protocol analysis
R&S
®
RTO6
646User Manual 1801.6687.02 ─ 05
The available operators:
●
Equal, Not equal
●
Less than, Greater than
●
Less or equal, Greater or equal
●
In range, Out of range
Remote command:
TRIGger<m>:SENT:
TDCN on page 1905
Nibbles ← Transmission Sequence setup
Displays the number of data nibbles of the transmission sequence.
Remote command:
BUS<m>:SENT:DNIBbles on page 1901
Data min ← Transmission Sequence setup
Sets the data pattern. Enter the bytes in msb first bit order. The maximum pattern
length is 64 bit. Waveform data is compared with the pattern byte-by-byte.
Remote command:
TRIGger<m>:SENT:TDMN on page 1905
Data max ← Transmission Sequence setup
The second data pattern is required to specify a range with conditions "In range" and
"Out of range".
Remote command:
TRIGger<m>:SENT:TDMX on page 1905
Serial Message setup
Configures the trigger conditions for a serial message.
Note: The displayed parameters depend on the selected "Sequence"
. The instrument
indicates the data setting parameters when you select "ID+Data", see "Type"
on page 643.
Sequence ← Serial Message setup
Selects the condition for triggering in a serial message.
You can trigger on the end of an identifier nibble or the combination of the identifier and
data nibble(s).
Remote command:
TRIGger<m>:
SENT:STYPe on page 1905
ID Type ← Serial Message setup
Selects the message ID format for the enhanced serial message type.
You can select either 4-bit or 8-bit message ID.
Remote command:
TRIGger<m>:SENT:SIDType on page 1906
Identifier Condition ← Serial Message setup
The available operators:
●
Equal, Not equal
SENT (option R&S R