Protocol analysis
R&S
®
RTO6
764User Manual 1801.6687.02 ─ 05
See: "Address" on page
766.
Set a mask pattern condition to trigger on a mask expected in the message.
See:
"Mask" on page 767.
Set a data pattern condition to trigger on data patterns expected in the message.
See: "Data" on page 767.
Master Ownership Handover ← Type
Available only for "Version"= "2.0"/"2.1".
Triggers on "Master Ownership Handover" command sequences.
Optionally, you can specify an MID pattern or an MID range to trigger only on com-
mand sequences that are sent to these slaves.
Master Write ← Type
Available only for "Version"= "2.0"/"2.1".
Triggers on "Master Write" command sequences. This sequence sends the register
address in the command payload, and sends two data frames.
You can refine the trigger condition:
Set a MID condition to trigger only on command sequences that are sent to the
specified MIDs.
See: "Slave Addr. /MID " on page 766.
Set a register address condition to trigger only on command sequences that write
data to the specified register.
See: "Address" on page 766.
Set a data pattern condition to trigger on data patterns expected in the message.
See: "Data" on page 767.
Master Read ← Type
Available only for "Version"= "2.0"/"2.1".
Triggers on "Master Read" command sequences. This sequence sends the register
address in the command payload, and reads two data frames.
You can refine the trigger condition:
Set a MID condition to trigger only on command sequences that are sent to the
specified MIDs.
See: "Slave Addr. /MID " on page 766.
Set a register address condition to trigger only on command sequences that write
data to the specified register.
See: "Address" on page 766.
Set a data pattern condition to trigger on data patterns expected in the message.
See: "Data" on page 767.
Master Context Transfer Write ← Type
Available only for "Version"= "2.1".
Triggers on "Master Context Transfer Write" command sequences.
You can refine the trigger condition:
Set an MID condition to trigger only on command sequences that are sent to the
specified MIDs.
See: "Slave Addr. /MID " on page 766