Remote command:
TRIGger<m>:
MPHY:
SSIC:ERENable on page 2321
TRIGger<m>:MPHY:SSIC:ERRor<n>:ENABle on page 2321
Set details
Opens a dialog to define frame specific settings.
AND / Field name / Condition ← Set details
This table lists the field numbers and names in the selected frame together with a sum-
mary of the user settings of checking conditions for each field and a checkbox to
enable the checking.
Select a field in the table to specify the checking conditions for this field in the "Set
details"
dialog.
The SSIC trigger frames and fields are the same as for USB3.1, see "Frame types"
on page 842.
Remote command:
TRIGger<m>:MPHY:SSIC:FRENable on page 2321
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:ENABle on page 2322
Data
Defines for the selected field, how a data check is executed.
"Condition"
Defining specific data or a data range requires to set the operator to
one of the following conditions: equal, not equal, less than, less than
or equal, greater than, greater than or equal, in range, out of range.
"Min"
Specifies data or sets the start value of a data range.
"Max"
Sets the end value of a data range, if "Condition" is set to "In range"
or "Out of range".
M-PHY and USB SSIC (option R&S R