Remote control commands
R&S
®
RTO6
2321User Manual 1801.6687.02 ─ 05
TRIGger<m>:MPHY:SSIC:ERENable.............................................................................
2321
TRIGger<m>:MPHY
:SSIC:ERRor<n>:ENABle................................................................ 2321
TRIGger<m>:MPHY:SSIC:FRENable.............................................................................2321
TRIGger<m>:MPHY:SSIC:FRAMe<n>:ENABle............................................................... 2321
TRIGger<m>:MPHY:SSIC:FIENable.............................................................................. 2322
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:ENABle.................................................. 2322
TRIGger<m>:MPHY:SSIC:BIT.......................................................................................2322
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:BIT.........................................................2322
TRIGger<m>:MPHY:SSIC:DMAX...................................................................................2323
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:DMAX.................................................... 2323
TRIGger<m>:MPHY:SSIC:DMIN....................................................................................2323
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:DMIN......................................................2323
TRIGger<m>:MPHY:SSIC:DOPerator............................................................................ 2323
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:DOPerator.............................................. 2323
TRIGger<m>:MPHY:SSIC:IMAX....................................................................................2324
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:IMAX......................................................2324
TRIGger<m>:MPHY:SSIC:IMIN..................................................................................... 2324
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:IMIN.......................................................2324
TRIGger<m>:MPHY:SSIC:IOPerator..............................................................................2325
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:IOPerator................................................2325
TRIGger<m>:MPHY:SSIC:ERENable <ErrorName>, <Enabler>
TRIGger<m>:MPHY:SSIC:ERRor<n>:ENABle <Enable>
Enables or disables the trigger on an error condition.
Suffix:
<m>
.
1..3
<n> *
Parameters:
<Enable> ON | OFF
*RST: ON
Example: Trigger on CRC and length errors:
TRIGger:
MPHY:SSIC:
ERRor1:ENABle ON
Enables CRC Error.
TRIGger:MPHY:SSIC:ERENable "Length Error",ON
Enables Length Error.
TRIGger<m>:MPHY:SSIC:FRENable <Frame>, <Enabler>
TRIGger<m>:MPHY:SSIC:FRAMe<n>:ENABle
<Enable>
Enables or disables the checking condition for the selected frame.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
<n> *
Specifies the field number within the frame.