EasyManua.ls Logo

R&S RTO6 - Page 1566

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTO6
1566User Manual 1801.6687.02 ─ 05
CALCulate:MATH<m>:FFT:BANDwidth[:RESolution]:RATio..............................................
1569
CALCulate:
MATH<m>:FFT:BANDwidth[:RESolution][:VALue]........................................... 1569
CALCulate:MATH<m>:FFT:WINDow:TYPE.....................................................................1569
CALCulate:MATH<m>:FFT:FRAMe:ARIThmetics............................................................ 1571
CALCulate:MATH<m>:FFT:FRAMe:COVerage?.............................................................. 1571
CALCulate:MATH<m>:FFT:FRAMe:MAXCount............................................................... 1571
CALCulate:MATH<m>:FFT:FRAMe:OFACtor.................................................................. 1572
CALCulate:MATH<m>:FFT:GATE:COUPling...................................................................1572
TIMebase:RACTime?................................................................................................... 1573
CALCulate:MATH<m>:FFT:GATE:ABSolute:STARt..........................................................1573
CALCulate:MATH<m>:FFT:GATE:ABSolute:STOP.......................................................... 1573
CALCulate:MATH<m>:FFT:GATE:MODE........................................................................1573
CALCulate:MATH<m>:FFT:GATE:RELative:STARt.......................................................... 1574
CALCulate:MATH<m>:FFT:GATE:RELative:STOP...........................................................1574
CALCulate:MATH<m>:FFT:GATE:ZCOupling..................................................................1574
CALCulate:MATH<m>:FFT:GATE[:STATe]...................................................................... 1575
CALCulate:MATH<m>:FFT:MAGNitude:LEVel.................................................................1575
CALCulate:MATH<m>:FFT:MAGNitude:RANGe.............................................................. 1575
CALCulate:MATH<m>:FFT:MAGNitude:SCALe...............................................................1575
CALCulate:MATH<m>:FFT:PHASe:SCALe..................................................................... 1577
CALCulate:MATH<m>:FFT:PHASe:SUPPression............................................................ 1577
CALCulate:MATH<m>:FFT:PHASe:THReshold............................................................... 1577
CALCulate:MATH<m>:FFT:PHASe:UNWRap..................................................................1577
CALCulate:MATH<m>:FFT:COUPled:WITH<1..8>...........................................................1578
CALCulate:MATH<m>:FFT:LOGScale <XAxisMode>
Defines the scaling method for the frequency (x-)axis of the spectrogram.
This command is only available if option R&S RTO6-K37 is installed.
Suffix:
<m>
.
1..8
Parameters:
<XAxisMode> LIN | LOG
LOG
Logarithmic scaling
LIN
Linear scaling
*RST: LIN
Usage: Asynchronous command
CALCulate:MATH<m>:FFT:STARt <StartFreq>
Defines the start frequency of the displayed frequency span.
Suffix:
<m>
.
1..8
math waveform
Spectrum analysis

Table of Contents

Other manuals for R&S RTO6

Related product manuals