Remote control commands
R&S
®
RTO6
1662User Manual 1801.6687.02 ─ 05
Usage: Setting only
SCPI confirmed
Asynchronous command
HCOPy:DEVice<m>:LANGuage <FileFormat>
Defines the file format for output of the display image to file.
To set the output to file, use
HCOPy:DESTination<1..2> with parameter 'MMEM'.
Suffix:
<m>
.
1..2
Selects the output configuration.
Parameters:
<FileFormat> PNG | JPG | BMP | TIFF | PDF
*RST: PNG
Example: See Chapter 24.3.5.1, "Saving a screenshot to file",
on page
1266
Usage: Asynchronous command
HCOPy:DEVice<m>:INVerse <InverseColor>
Inverts the colors of the output, i.e. a dark waveform is printed on a white background.
Screenshots are inverted per default when you save using remote commands. Turn
inversion of
f if you want the screen display in the screenshot.
See also:
HCOPy:WBKG on page 1662
"White background" on page 477
Suffix:
<m>
.
1..2
Selects the output configuration.
Parameters:
<InverseColor> ON | OFF
*RST: ON
Usage: Asynchronous command
HCOPy:WBKG <WhiteBackground>
Inverts the background color. So you can print waveforms with normal waveform col-
lors on white background.
If both
HCOPy:WBKG and HCOPy:DEVice<m>:INVerse are ON, the instrument
inverts the background twice, and it appears black.
See also: "White background" on page 477.