Remote control commands
R&S
®
RTO6
1691User Manual 1801.6687.02 ─ 05
Usage: Query only
BUS<m>:I2C:FRAMe<n>:BYTE<o>:ACCess?
Returns the acknowledge bit value of the specified data byte.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
<o> *
Selects the byte number.
Return values:
<AckBit> INComplete | ACK | NACK | EITHer
*RST: INComplete
Usage: Query only
BUS<m>:I2C:FRAMe<n>:BYTE<o>:ACKStart?
Returns the start time of the acknowledge bit of the specified byte.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
<o> *
Selects the byte number.
Return values:
<AckBitStart>
To set the value format, use FORMat:BPATtern
.
The values below range, increment and reset are decimal
values.
Range: -100E+24 to 100E+24
*RST: 0
Default unit: s
Usage: Query only
BUS<m>:I2C:FRAMe<n>:BYTE<o>:COMPlete?
Returns if the indicated byte is completely contained in the acquisition.
Suffix:
<m>
.
1..4
Selects the serial bus.
Protocols