BUS<m>:CMSB:NRZ:HYSTeresis:ENBLe......................................................................
1760
BUS<m>:CMSB:NRZ:THReshold:
PRESet......................................................................1761
BUS<m>:CMSB:NRZ:THReshold:COUPling...................................................................1761
BUS<m>:CMSB:BITRate:ENABle..................................................................................1762
BUS<m>:CMSB:BITRate:VALue....................................................................................1762
BUS<m>:CMSB:GAPTime:ENABle................................................................................1762
BUS<m>:CMSB:GAPTime:VALue..................................................................................1762
BUS<m>:CMSB:ADDFrame..........................................................................................1763
BUS<m>:CMSB:FCOunt?.............................................................................................1763
BUS<m>:CMSB:CLR................................................................................................... 1763
BUS<m>:CMSB:FRAMe<n>:TYPE................................................................................1763
BUS<m>:CMSB:FRAMe<n>:APPend.............................................................................1764
BUS<m>:CMSB:FRAMe<n>:CCOunt?...........................................................................1764
BUS<m>:CMSB:FRAMe<n>:CELL<o>:NAME.................................................................1764
BUS<m>:CMSB:FRAMe<n>:CELL<o>:BITCount............................................................ 1764
BUS<m>:CMSB:FRAMe<n>:CELL<o>:CONDition.......................................................... 1765
BUS<m>:CMSB:FRAMe<n>:CELL<o>:FORMat..............................................................1765
BUS<m>:CMSB:FRAMe<n>:CELL<o>:BITorder..............................................................1766
BUS<m>:CMSB:FRAMe<n>:CELL<o>:CRGB.................................................................1766
BUS<m>:CMSB:EXRBits..............................................................................................1766
BUS<m>:CMSB:FRAMe<n>:CELL<o>:CLMN.................................................................1766
BUS<m>:CMSB:LOAD................................................................................................. 1767
BUS<m>:CMSB:SAVE..................................................................................................1767
BUS<m>:CMSB:CODing <CodingStandard>
Selects the custom serial bus coding standard.
Suffix:
<m>
.
1..4
Parameters:
<CodingStandard> MANC | MANT | NRZ | NRZU
MANC
Manchester (normal polarity)
MANT
Manchester II (inverted polarity).
Note that some additional subtle dif
ferences between MANC
and MANT require separate protocols.
NRZ
NRZ (non-return-to-zero), clocked
NRZU
NRZ (non-return-to-zero), unclocked
*RST
: MANC
Protocols