EasyManua.ls Logo

R&S RTO6 - Page 1801

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTO6
1801User Manual 1801.6687.02 ─ 05
TRIGger<m>:CAN:DMAX.............................................................................................
1805
TRIGger<m>:
CAN:BORDer.......................................................................................... 1805
TRIGger<m>:CAN:DLCCondition...................................................................................1805
TRIGger<m>:CAN:DLC................................................................................................ 1805
TRIGger<m>:CAN:NDBYtes?........................................................................................1806
TRIGger<m>:CAN:FDATa:DPOPerator...........................................................................1806
TRIGger<m>:CAN:FDATa:DPOSition............................................................................. 1806
TRIGger<m>:CAN:FDATa:DPTO................................................................................... 1807
TRIGger<m>:CAN:ACKerror......................................................................................... 1807
TRIGger<m>:CAN:BITSterror........................................................................................1807
TRIGger<m>:CAN:CRCerror.........................................................................................1807
TRIGger<m>:CAN:FORMerror...................................................................................... 1807
TRIGger<m>:CAN:FDATa:SCERror............................................................................... 1808
TRIGger<m>:CAN:TYPE <Type>
Selects the trigger type for CAN analysis.
See: "Trigger type" on page 587.
Parameters:
<Type> STOF | FTYP | ID | IDDT | ERRC
ST
OF
ST
art Of Frame: triggers on the first edge of the dominant SOF
bit (synchronization bit).
FTYP
Frame TYPe: triggers on a specified frame type (data, remote,
error, or overload) and on the identifier format.
To set the frame type, use TRIGger<m>:CAN:FTYPe. ´Set the
identifier format with TRIGger<m>:CAN:ITYPe
ID
IDentifier: Sets the trigger to one specific identifier or an identi-
fier range. To set the identifier, use TRIGger<m>:CAN:
ICONdition, TRIGger<m>:CAN:IMIN, and TRIGger<m>:
CAN:IMAX.
IDDT
IDentifier and DaTa: Combination of identifier and data condi-
tions To set the identifier condition, use TRIGger<m>:CAN:
ICONdition, TRIGger<m>:CAN:IMIN, and TRIGger<m>:
CAN:IMAX.
To set the data condition, use TRIGger<m>:CAN:DCONdition,
TRIGger<m>:CAN:DMIN, and TRIGger<m>:CAN:DMAX.
ERRC
ERRor Condition: Define the error types with
TRIGger<m>:CAN:ACKerror,
TRIGger<m>:CAN:BITSterror,
TRIGger<m>:CAN:CRCerror,
TRIGger<m>:CAN:FORMerror,
TRIGger<m>:CAN:FDATa:SCERror on page 1808.
Protocols

Table of Contents

Other manuals for R&S RTO6