Parameters:
<DataPositionTo> Range: 0 to 255
Increment: 1
*RST: 0
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:FCONdition <SearchName>,<IdOperator>
SEARch:TRIGger:FLXRay:FCONdition? <SearchName>
Sets the operator to set a frame ID or a frame ID range.
Parameters:
<IdOperator> OFF | ANY | EQUal | NEQual | LTHan | LETHan | GTHan |
GETHan | INRange | OORange
OFF = ANY
The frame ID is not relevant for the search condition.
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one frame ID to
be set with
SEARch:TRIGger:FLXRay:FMIN.
INRange | OORange
In range, Out of range: Set the minimum and maximum value of
the range with SEARch:TRIGger:FLXRay:FMIN and SEARch:
TRIGger:FLXRay:FMAX.
*RST: EQUal
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:FMAX <SearchName>,<IdPatternTo>
SEARch:TRIGger:FLXRay:FMAX?
<SearchName>
Sets the the end value of an identifier range if the condition SEARch:TRIGger:
FLXRay:FCONdition is set to INRange or OORange.
Parameters:
<IdPatternTo> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286.
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:FMIN <SearchName>,<IdPattern>
SEARch:TRIGger:FLXRay:FMIN? <SearchName>
Specifies a frame identifier pattern - the number of the slot - or sets the the start value
of an identifier range.