Remote control commands
R&S
®
RTO6
1922User Manual 1801.6687.02 ─ 05
SEARch:TRIGger:SENT:SDCN <SearchName>,<SMDataOperator>
SEARch:TRIGger:SENT
:SDCN
? <SearchName>
Sets the operator to set a specific data pattern or a data pattern range.
Parameters:
<SMDataOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater than,
Greater or equal than. These conditions require one data pattern
to be set with
SEARch:TRIGger:SENT:SDMN.
INRange | OORange
In range / Out of range. To define the range set the minimum
and maximum values with SEARch:TRIGger:SENT:SDMN and
SEARch:TRIGger:SENT:SDMX.
*RST: EQUal
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:SENT:SDMN <SearchName>,<SMDataPattern>
SEARch:TRIGger:SENT:SDMN
? <SearchName>
Specifies a data pattern, or sets the start value of a data pattern range.
Parameters:
<SMDataPattern> Numeric or string pattern, Chapter 24.4.6, "Bit pattern parame-
ter", on page 1286. The string parameter accepts the bit value X
(don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:SENT:SDMX <SearchName>,<SMDataPatternTo>
SEARch:TRIGger:SENT
:SDMX? <SearchName>
Sets the end value of an identifier range for SEARch:TRIGger:SENT:SDCN
INRange or OORange.
Parameters:
<SMDataPatternTo> Numeric or string pattern, Chapter 24.4.6, "Bit pattern parame-
ter", on page 1286. The string parameter accepts the bit value X
(don't care).
Parameters for setting and query:
<SearchName>
Protocols