Protocol analysis
R&S
®
RTO6
913User Manual 1801.6687.02 ─ 05
Remote command: 
SEARch:
TRIGger:MPHY:
TYPE on page 2300
Start of frame ← Type
Searches for the start of an M-PHY or a UniPro frame.
Burst ← Type
Searches for an M-PHY burst.
Adapt ← Type
Searches for an M-PHY Adapt frame. This control frame is used for clock/bit synchroni-
zation.
LCC ← Type
Searches for an M-PHY Line Control Command (LCC) frame that matches the speci-
fied LCC Type or any WORD condition.
This control frame is used for configuring the line to a different state or mode depend-
ing on the LCC type.
DL PDU SOF ← Type
Searches for a UniPro Downlink Protocol Data Unit (DL PDU) Start Of Frame (SOF)
that matches the specified TC, Data or Index condition.
DL PDU COF ← Type
Searches for a UniPro DL PDU Continuation Of Pre-empted Frame (COF) that
matches the specified TC, Data or Index condition.
DL PDU EOF ← Type
Searches for a UniPro DL PDU End Of Frame (EOF) that matches the specified FSN
or CRC condition.
DL PDU NAC ← Type
Searches for a UniPro DL PDU Negative Acknowledgment Control (NAC) frame that
matches the specified RReq or CRC condition.
DL PDU AFC ← Type
Searches for a UniPro DL PDU Acknowledgement and L2 Flow Control (AFC) frame
that matches the specified TC, CReq, FSN, Credit or CRC condition.
PACP ← Type
Searches for a UniPro PHY Adapter Control Protocol (PACP) frame that matches the
specified PACP Begin, PACP Function ID, Data, Index or CRC condition.
This control frame is used mainly for power mode change and L1.5 link management.
It is also used in scrambling request.
Trigger Upper0 ← Type
Searches for a Trigger Upper0 frame. This control frame is used for link startup
sequence.
M-PHY and USB SSIC (option R&S R
T
O6-K580 and K570)