Protocol analysis
R&S
®
RTO6
617User Manual 1801.6687.02 ─ 05
"Identifier +
Data"
Searches for a combination of identifier and data condition. The
instrument triggers at the end of the last byte of the specified data
pattern.
The identifier conditions are the same as for the "Identifier" trigger
type, see "Identifier setup: Condition, Frame ID min, Frame ID max
"
on page
612.
Data conditions are set with "Data setup: Data length, Transfer, Con-
dition, Data min, Data max" on page 613.
"Wakeup
frame"
Searches for wakeup frames.
"Error condi-
tion"
Identifies various errors in the frame, see "Error conditions
"
on page
614.
Remote command:
SEARch:TRIGger:LIN:SSOFrame on page 1853
SEARch:TRIGger:LIN:SFIDentifier on page 1853
SEARch:TRIGger:LIN:IDENtifieror on page 1853
SEARch:TRIGger:LIN:SIDData on page 1853
SEARch:TRIGger:LIN:WUFRame on page 1854
SEARch:TRIGger:LIN:SERRor on page 1854
Identifier setup: Condition, Frame ID min, Frame ID max
The identifier setup consists of the condition and one or two frame ID patterns.
The identifier setup settings are the same as in the LIN trigger setup, see "Identifier
setup: Condition, Frame ID min, Frame ID max" on page 612.
Remote command:
SEARch:TRIGger:LIN:ICONdition on page 1854
SEARch:TRIGger:LIN:IMIN on page 1855
SEARch:TRIGger:LIN:IMAX on page 1855
Data setup: Condition, Data min, Data max, Data length, Transfer
The data setup consists of the transfer direction, the data length, the condition, and
one or two data patterns.
The data setup settings are the same as in the LIN trigger setup, see "Data setup: Data
length, Transfer, Condition, Data min, Data max" on page 613.
Remote command:
SEARch:TRIGger:LIN:DCONdition on page 1856
SEARch:TRIGger:LIN:DMIN on page 1856
SEARch:TRIGger:LIN:DMAX on page 1856
SEARch:TRIGger:LIN:DLECondition on page 1857
SEARch:TRIGger:LIN:DLENgth on page 1858
SEARch:TRIGger:LIN:BORDer on page 1857
Identifier OR setup: Monitor, Frame ID
The identifier OR setup consists of the monitor and frame ID.
The identifier OR setup settings are the same as in the LIN trigger setup, see "Identifier
OR setup: Monitor, Frame ID" on page 613
LIN (option R&S R