Jitter analysis and clock data recovery
R&S
®
RTO6
1085User Manual 1801.6687.02 ─ 05
Remote command:
ADVJitter<m>:
SIGNal:
GATE:STATe on page 2491
Coupling mode ← Gating
Selects if the gate is coupled to the zoom or cursor.
To use the coupling mode, you have to enable a cursor or zoom first.
Remote command:
ADVJitter<m>:SIGNal:GATE:COUPling on page 2489
Cursor / Zoom ← Gating
Selects the cursor/ zoom the gate is coupled to, if "Coupling mode" is set to "Cursor
"/"Zoom".
Remote command:
ADVJitter<m>:SIGNal:GATE:CURSor on page 2489
ADVJitter<m>:SIGNal:GATE:ZDIagram on page 2491
Mode ← Gating
Selects if the gate area is defined in relative values (percent) or absolute.
Remote command:
ADVJitter<m>:SIGNal:GATE:RANGe:MODE on page 2490
Start / Stop ← Gating
Sets the start/stop time of the gate area.
Remote command:
ADVJitter<m>:SIGNal:GATE:RANGe:ABSolute:STARt on page 2489
ADVJitter<m>:SIGNal:GATE:RANGe:ABSolute:STOP on page 2490
Relative start / stop ← Gating
Sets the relative start/stop of the gate area in percent.
Remote command:
ADVJitter<m>:SIGNal:GATE:RANGe:RELative:STARt on page 2490
ADVJitter<m>:SIGNal:GATE:RANGe:RELative:STOP on page 2490
Clock / CDR
Selects if a clock or a CDR signal is used as a reference signal.
"CDR"
Uses software clock data recovery.
"Clock"
Uses an explicit clock signal. The signal has to be provided on an
additional channel.
Remote command:
ADVJitter<m>:SIGNal:
REFSource on page 2486
Reference source
Selects the reference source for the clock/CDR signal.
Remote command:
ADVJitter<m>:SIGNal:CLKSource on page 2487
ADVJitter<m>:SIGNal:CDRMode on page 2486
Advanced jitter and noise (option R&S R