1/05
2-134
DocuColor 12/DCCS50
9-667 VH/VM Out Of Range RAP
Reissue
Status Indicator RAPs
9-667 VH/VM Out Of Range RAP
The selected LD value was out of range.
Initial Actions
• Refer to BSD 9.1 and BSD 9.15 for the following procedure.
• Clean the ESV Sensor.
• Check that P/J141 on th
e ESV Sensor, and P/J422A on the IOT Drive PWB are firmly
connected.
Procedure
Perform the following in the order listed.
• Go to the IQ 38 Charge Corotron HVP
S RAP and check the Charge Corotron HVPS for
proper operation.
• Ensure that the Charge Corotron Wire and Grid are in good condition.
•Go to Flag
6 and Flag 7 on BSD 9.1. Check the wires for an open circuit or a short circuit.
If the wires are good, replace the ESV Sensor (PL 5.1). If the problem continues, replace
the IOT Drive PWB (PL 9.2).
• If the fault was declared during the VH portion of
dC9
33, replace the Xerographic Module
(Drum CRU) (Machine Consumables, Section 6).
If the fault was declared during the VM portion of dC933, replace the ROS Assembly (PL
4.1).