1/05
6-86
DocuColor 12/DCCS50
dC131 Procon1 NVM List (773), dC131 Procon2 NVM
Reissue
General Procedures
dC131 Procon2 NVM List (774)
773-592 ADC Vpatch S [M] 0 0-65535 M-color: ADC patch measurement
value (Mirror element)
773-593 ADC Vpatch S [C] 0 0-65535 C-color: ADC patch measurement
value (Mirror elem
ent)
773-594 ADC Vpatch S [K] 0 0-65535 K-color: ADC patch measurement
value (Mirror elem
ent)
773-596 ADC Vpatch D [Y] 0 0-65535 Y-color: DSP: ADC patch measure-
ment value (Diffusion element)
773-597 ADC Vpatch D [M] 0 0-65535 M-color: DSP: ADC patch measure-
ment value (Diffusion element)
773-598 ADC Vpatch D [C] 0 0-65535 C-color: DSP: ADC patch measure-
ment value (Diffusion element)
773-599 ADC Vpatch D [K] 0 0-65535 K-color: DSP: ADC patch measure-
ment value (Diffusion element)
773-606 Radc patch [Y] 0 0-65535 Y-color: ADC patch measurement
densit
y
773-607 R
adc patch [M] 0 0-65535 M-color: ADC patch measurement
density
773-608 R
adc patch [C] 0 0-65535 C-color: ADC patch measurement
density
773-609 R
adc patch [K] 0 0-65535 K-color: ADC patch measurement
density
Ta
ble 1 Procon 1 NVM List (773)
Ch
ain-
L
ink Name Default Range Description
Table 1 Procon2 NVM List (774)
Chain-
Link Name Defa
ult Range Description
774-001 CC I TOT 717 0-1023 Current total CC electric current
(0=0 m
icro
ampere 1023=1000
micro ampere)
774-004 CC V GRID 717 0-1023 Current grid CC voltage (0=0V
1023=1000V)
774-005 CC V GRID DFLT 717 0-1023 Grid voltage to check the CC
out
put (0=0V 1023=1000V)
774-008 BO
TTLE NOT IN POSI-
TION
0 Waste bottle (0=Yes 1=No)
774-015 BOTTLE EMP
COUNTER
0 EM
PTY counter
774-017 BOTTLE EMP HOLD 0 EMP Counter record when the
Bottle G
oal was determined.
774-018 BOTTLE FULL 0 Collection status FLG (0= Empty
1= Near Fu
ll 2= Full)
774-019 BOTTLE FULL
COUNTER
0 Near F
ull Counter
774-020 BOTTLE GOAL 300 0-65536 Threshold to generate a Bottle
Full
Fault
774-029 PCC dC 12 130 0-255 DC current to reduce cycle 1-2
(0=0 micro
ampere 255=800
micro ampere)
(If out of the range, MAX value is
out
put.
)
774-033 PCC dC ER 96 0-255 DC current for elimination= Nom-
inal (0=0 micro ampere 255=800
micr
o ampere)
(I
f out of the range, MAX value is
out
put.
)
774-056 X CRU TYPE 48=FSMA
49=T&M
0-255 Drum
unit type (0XAA)
774-057 CRU COUNT MODE 0 0-1 Shut-down condition setting flag
0= Shut-down with the set
count
va
lue.
1= Shut-down when
exceedi
ng the set count
value.
774-070 DRUM CYCLEUPPER
L
0 Drum cycle count: L side count
(0-99)
774-071 DRUM CYCLEUPPER
H
3400 Drum cycle count: H side count
(0-65535)
manuals4you.commanuals4you.com