1/05
2-15
DocuColor 12/DCCS50
3-311 IOT-SYS Logic Fail RAP, 3-315 IOT/IPS Com-
Status Indicator RAPs
Reissue
3-311 IOT-SYS Logic Fail RAP
The IOT-SYS Software Logic Failure was detected after a certain time period (the NVM value).
Initial Actions
Refer to BSD 3.12 Monitoring in this procedure:
Procedure
Perform the following:
PO/PO the machine
Reset the connectors on the IOT CPU PWB (PL 9.2)
Replace the IOT CPU PWB (PL 9.
2)
3-315 IOT/IPS Communications Fail RAP
The 3-315 Fault Code indicates that a communication failure between the IOT PWB and the
Post IPS PWB was detected.
Initial Actions
Ensure that P571 is firmly connected to the Post IPS PWB.
Refer to BSD 3.2 PWB Communications (IPS) and BSD 3.12 Monitoring in this proce-
dure:
Procedure
There is +3.5 VDC from J 570 pin 1 to pin 6 on the Post IPS PWB.
YN
Go to F
lag 5 on BSD 3.2. Check for an open or a short circuit to GND. If the wires are OK,
replace t
he IIT LVPS (PL 3.5).
There is +3.5 VDC from J 517 pin 3 to pin 4 on the Pre IPS PWB.
YN
Go to F
lag 6 on BSD 3.2. Check for an open or a short circuit to GND. If the wires are OK,
replace t
he IIT LVPS (PL 3.5).
There is +5 VDC from J 517 pin 1 to pin 2 on the Pre IPS PWB.
YN
Go to F
lag 6 on BSD 3.2. Check for an open or a short circuit to GND. If the wires are OK,
replace t
he IIT LVPS (PL 3.5).
There is +13.3 VDC from J 517 pin 7 to pin 5 on the Pre IPS PWB.
YN
Go to F
lag 6 on BSD 3.2. Check for an open or a short circuit to GND. If the wires are OK,
replace t
he IIT LVPS (PL 3.5).
Perform the following:
PO/PO the machine
•Go to Flag 3 and F
lag 4 on BSD 3.2. Check the following wires for a short/open circuit:
Between Post IPS PWB P571-23 and
IOT CPU PWB P/J404-A13
Between Post IPS PWB P571-24 and
IOT CPU PWB P/J404-A14
Between Post IPS PWB P571-25 and
IOT CPU PWB P/J404-A11
Between Post IPS PWB P571-26 and
IOT CPU PWB P/J404-A12
Replace the PRE IPS PWB (PL 3.5)
Replace the IOT CPU PWB (PL 9.
2)
Replace the Post IPS PWB (PL 3.
5)
Replace the MEM SYS PWB (PL 3.
5)