1/05
6-142
DocuColor 12/DCCS50
Color Balance Setup (dC919 UI Diagnostics) (IIT in-
Reissue
General Procedures
Color Balance Setup (dC919 UI Diagnostics) (IIT installed
machine only)
Purpose
• To correct the YMCK Color Balance.
• Take a 4C copy in the Photo Mode. Visually check the copy. Reset the YMCK Color Bal-
ance Value.
NOTE: Run this function at the customer’s request, afte
r the automatic gray-scale is corrected.
NOTE: The Hi-Light Setup must be performed before running this function.
NOTE: This section only describes the setup in the UI-Diagnostics. For details, see IOT High-
li
ght Setup (dC918 UI Diagnostics).
Procedure
1. Enter the UI Diagnostics Mode. Refer to How to Enter/Exit the UI (IOT) Diagnostics.
2. Select the following:
Max Setup→Colo
r Balance Setup.
3. Place Test Pattern
(82E10810) on the Platen Glass. Select the Start Button.
Tak e a PG Print in t
he following mode:
a. APS, 100%, Normal paper, LUTON
NOTE
: If each color has no defects in density, go to Step 4.
If there are defects in color density, adjust the color balance for colors with defects using
the U
I.
4. Select Clos
e to return to the Max Setup Screen.
manuals4you.commanuals4you.com