1/05
4-79
DocuColor 12/DCCS50
REP 6.1.2, REP 6.1.3
Repairs and Adjustments
Reissue
Figure 2 Position the Bracket
2. Adjust the Rotary Home Position Sensor (ADJ 6.1.
1).
REP 6.1.3 Rotary Latch Lever
Parts List on PL 6.1
Removal
WARNING
Turn power off and disconnect the power plug.
1. Remove the Right Upper Cover (PL 11
.2 Item 1)
2. Remove the Rotary PWB (Steps 1 - 3 of REP 6.1.
1)
3. Disconnect the connector (Figure 1).
1.
Loosen the screws (2).
2. Disconnect the connectors (3).
3. Release the clamps (2) and remove the wire.
4. Pull out the connector from the hole.
Figure 1 Disconnect the Connectors
4. Hook the bracket hooks (Figure 2
).
1. Hook the bracket hooks (2).