DocuColor 12/DCCS50
15-363 IIT Memory Fail RAP, 15-365 X Comm Fail RAP
Reissue
Status Indicator RAPs
15-363 IIT Memory Fail RAP
The control logic detected a memory clearance error.
Initial Actions
• Refer to BSD 6.7 in the following procedure:
• Ensure that P/J514 on t
he Pre IPS PWB and the MEM SYS PWB are fully seated.
Procedure
PO/PO the machine. If the fault continues, replace the following:
• MEM SYS PWB (PL 3.
5)
• Pre IPS PWB (PL 3.
5)
15-365 X Comm Fail RAP
The control logic detected that the POST IPS PWB could not detect a change in the signal
from the Pre IPS PWB.
Initial Actions
• Refer to BSD 6.7 in the following procedure:
• Ensure that P/J5
14 on the Pre IPS PWB, P/J560, P/J561 between the MEM SYS PWB
and the POST IPS PWB are fully seated.
Procedure
PO/PO the machine. If the fault continues, replace the following:
• POST IPS PWB (PL 3.
5)
• Pre IPS PWB (PL 3.5)
• MEM SYS PWB (PL 3.
5)