1/05
2-216
DocuColor 12/DCCS50
14-380 SOS Fail 1 RAP, 14-384 SOS Fail 2 RAP
Reissue
Status Indicator RAPs
14-380 SOS Fail 1 RAP
The SOS Interval became longer than normal while the Polygon Motor was energized.
Initial Actions
• Refer to BSD 6.5, BSD 6.6, and BSD 6.7 in the following procedure.
• Verify that P/J42
0A on the IOT Drive PWB is firmly seated.
• Verify that P/J3
45 and P/J341 on the LDD PWB is firmly seated.
• Verify that P/J3
47 and P/J342 on the ROS are firmly seated.
• Verify that P/J3
99 on the Halftone PWB is firmly seated.
Procedure
Replace the following:
• ROS (PL 4.1)
•IOT Drive PWB (PL 9.2)
14-384 SOS Fail 2 RAP
The SOS Interval became shorter than normal while the Polygon Motor was energized.
Initial Actions
• Refer to BSD 6.5, BSD 6.6, and BSD 6.7 in the following procedure.
• Verify that P/J
420A on the IOT Drive PWB is firmly seated.
• Verify that P/J
345 and P/J341 on the LDD PWB is firmly seated.
• Verify that P/J
347 on the ROS is firmly seated.
• Verify that P/J
342 on the ROS is firmly seated.
Procedure
Replace the following:
• ROS (PL 4.1)
•I
OT Drive PWB (PL 9.2)
manuals4you.commanuals4you.com