1/05
2-22
DocuColor 12/DCCS50
3-393 Half-Tone EEP-ROM Limit Failure RAP, 3-394
Reissue
Status Indicator RAPs
3-393 Half-Tone EEP-ROM Limit Failure RAP
This fault code is declared when the limit of the allowable number of times to write on to the
EEP-ROM of the Half-Tone PWB is reached.
Initial Actions
• Refer to BSD 3.12 Monitoring in this procedure:
Procedure
PO/PO the machine.
Fault Code 3-393 is still declared.
YN
If intermittent operation is suspected, inspect the IOT CPU PWB and the Half-Tone PWB
f
or
loose connections or any obvious electrical/mechanical cause for malfunction.
Replace the Half Tone PWB (PL 9.
2).
3-394 IOT EEP-ROM Limit Failure RAP
This fault code is declared when the limit of the allowable number of times to write on the EEP-
ROM of the IOT CPU PWB is reached.
Initial Actions
• Refer to BSD 3.12, Monitoring in this procedure:
Procedure
PO/PO the machine.
Fault Code 3-394 is still declared.
YN
If intermittent operation is suspected, inspect the IOT CPU PWB, and the Half-Tone PWB
f
or
loose connections or any obvious electrical/mechanical cause for malfunction.
Replace the IOT CPU PWB (PL 9.
2).