DocuColor 12/DCCS50
dC135 HFSI Counters, dC135 HFSI Counter List
Reissue
General Procedures
dC135 HFSI Counters
Purpose
This routine displays the service life (Threshold) and the current value (count) of the periodic
replacement parts. Replacement life change, and current value resets are possible.
Procedure
1. Enter the Service Diagnostics Mode. Refer to Entering the Service Diagnostic Mode
using the PWS.
2. Select Mainten
ance on the Service Entry Screen. The All Jams screen displays as the
default screen.
3. Select HFS
I Counters (dC135) tab on the Maintenance screen.
4. The HFSI
Counters screen displays the replacement life (Threshold) and the current
value (count) of the periodic replacement parts. Two vertical tabs allow display of all HFSI
counters, or only those counters that are over threshold.
5. Refer to Det
ailed M
aintenance Activities in Section 1. Perform the listed Service Action for
all HSFI counters that are at or near threshold.
6. To reset the count after replacing the parts, select the appropriate HFSI item, then select
the Reset Co
unter button.
dC135 HFSI Counter List
NOTE: Refer to Detailed Maintenance Activities in Section 1.