1/05
6-87
DocuColor 12/DCCS50
dC131 Procon2 NVM List (774), dC131 Procon3
General Procedures
Reissue
dC131 Procon3 NVM List (775)
774-074 DISP TIMELOWER 0 Toner dispense time: L side
value (0-3599/Unit: 0.1 second)
774-075 DISP TIMEUPPER 2000 Toner dispense time: H side
value (0-65535/Unit
: 0.1 hour)
774-081 SIGN DRUM 0 Drum cycle counter: Counter
sign (0
: Positive, 256: Negative)
Upper byte: Drum cycle counter
si
gn
774-173 AUGE
R STOP 0 0-3 Auger rotation detection Status
flag
0= Norm
al
1= Normal now but abnormal
rot
at
ion before
2= Abnormal
3= Machine stop)
774-174 AUGER COUNTER 0 0-65535 Collection Auger Stop counter
(
Un
it= Print)
774-175 AUGER GOAL 200 0-65535 Threshold to generate the
Cleaning A
UGER Broken Fault
Table 1 Procon2 NVM List (774)
Chain-
L
ink Name Default Range Description
Table 1 Procon3 NVM List (775)
Chain-
Link Name Defau
lt Range Description
775-001 Vclean TRC Fail 0 0-65535 TRC ADC non-develop-
ment: Output Fault counter
775-002 TRC MINI Fail [Y] 0 0-65535 TRC patch fault counter (Y)
775-003 TRC MINI Fail [M] 0 0-65535 TRC patch fault counter (M)
775-004 TRC MINI Fail [C] 0 0-65535 TRC patch fault counter (C)
775-005 TRC MINI Fail [K] 0 0-65535 TRC patch fault counter (K)
775-019 MINI Timer SW 1 0-1 For Run Length=0 uncon-
trollable fault at Maxsetup
(T
one Up/D
own)
0= Tone Up/Down
minimum
run p
ages=3
(Mixing)
1 or more= Tone Up/
Down m
inimum
run
page=0
<1 or more= Not available
i
n PW