1/05
2-217
DocuColor 12/DCCS50
14-388 XPC ASIC Fail RAP
Status Indicator RAPs
Reissue
14-388 XPC ASIC Fail RAP
The Control Logic detected a ROS Pickup ASIC Failure
Initial Actions
• Refer to BSD 1.1, BSD 6.6 and BSD 6.7 in the following procedure:
• Ensure that P/J398 on t
he Halftone PWB and the P/J345 and P/J341 on the LDD PWB
are fully seated.
•Go to Flag
2 and Flag 3 on BSD 6.5 and check the wires for an open or shorted circuit.
Procedure
PO/PO the machine. If the fault continues, go to 14-376 Half Tone PWB Fail RAP.