1/05
4-82
DocuColor 12/DCCS50
REP 6.1.4
Reissue
Repairs and Adjustments
REP 6.1.4 Bias Brush
Parts List on PL 6.1
Removal
WARNING
Turn power off and disconnect the power plug.
1. Remove the following parts:
a. Cover Assembly (PL 6.5 It
em 18)
b. Trickle Toner Bottle (PL 6.5 I
tem 23)
2. Remove the Drum Unit (REP 5.3.
1).
3. Remove the Bias Brush (Figu
re 1).
1. Remove the screws (2).
2. Remove the fasten terminal.
3. Remove the Bias Brush.
Figure 1 Remove the Bias Brush
Installation
NOTE: Make sure that the protruding part of the Bias Brush is in the frame hole (Figure 2).
Figure 2 Reassembly
1. Reinstall the parts in the reverse order of disassembly.