1/05
6-128
DocuColor 12/DCCS50
dC924 TRC Adjust / dC939 TRC Check PG, dC929 Max
Reissue
General Procedures
dC924 TRC Adjust / dC939 TRC Check PG
NOTE: NOT TO BE USED AT THIS TIME.
Purpose
To manually fine adjust the low/medium/high densities (TRC) for each color.
NOTE: Although it appears that the densities can be adjusted independently for different
scr
een types, this is not the case. An adjustment for one screen type will affect all of the
screens (300, 150C, 200R, and 600). Also, there is quite a bit of overlap among the low,
medium, and high densities. For these reasons, it is recommended that dC924/939 not be
used.
dC929 Max Setup
Purpose
The system displays the following Setup functions which you can use to set the image quality.
1. dC945 IIT Calibration (See dC945 II
T Calibration) (IIT installed machine only)
2. dC934 ADC/AGC Setup (See dC934 ADC/AGC Set
up)
3. dC933 VH/VM Setup (See dC933 VH/V
M Setup)
4. dC918 IOT Highlight Setup (See dC918 IO
T Highlight Setup)
5. dC922 TRC Control/Toner Density Adjustment (See dC922 TRC Control/
Toner Density
Adjustment)
6. dC924 TRC Adjustment/939TRC Check (See dC924 TRC Adjus
t / dC939 TRC Check
PG)
7. dC919 Color Balance Setup (See dC919 Color B
alance Setup (IIT installed machine
only)) (IIT installed machine only)
8. dC923 PROCON PG (See dC923 PROCO
N PG).
NOTE: For the execution sequence of the Max Setup Functions, see Adjustments Section 4:
ADJ 9.1.
1 Max Setup (dC929).
NOTE: If a 3-510 fault occurs while performing Max Setup, ensure that Automatic Tray switch-
ing for Trays 1 - 4 is enabled in Customer Tools