1/05
6-72
DocuColor 12/DCCS50
dC131PH NVM List (761)
Reissue
General Procedures
761-290 PASS REGI SEN-
SOR 10(USED
TRAY
3)
DSP: Pass
R
egiS
NR10 Tray3
0 None Measurement result: Register Sensor
O
FF
timing from the Registration Feed
(paper fed from Tray 2).
Default=0ms
Range=None
Theoretical value=Paper
lengt
h÷0.
221168mm/s (Normal
paper)
Theoretical value=Paper
lengt
h÷0.
130mm/s (This paper 1)
Unit=2ms/step (Normal paper)
Unit=3.3832ms/step (This paper 1)
Last storage location - see 761-368.
761-291 PASS REGI SEN-
SOR 1(USED
TRAY
4)
0 None Measurement result: Register Sensor
O
FF
timing from the Registration Feed
(paper fed from Tray 4).
Theoretical value=Paper
lengt
h÷0.
221168mm/s (Normal
paper)
Theoretical value=Paper
lengt
h÷0.
130mm/s (This paper 1)
Unit=2ms/step (Normal paper)
Unit=3.3832ms/step (This paper 1)
Last storage location - see 761-370.
761-292 PASS REGI SEN-
SOR 2(USED
TRAY
4)
0 None Measurement result: Register Sensor
O
FF
timing from the Registration Feed
(paper fed from Tray 4).
Theoretical value=Paper
lengt
h÷0.
221168mm/s (Normal
paper)
Theoretical value=Paper
lengt
h÷0.
130mm/s (This paper 1)
Unit=2ms/step (Normal paper)
Unit=3.3832ms/step (This paper 1)
Last storage location - see 761-370.
Table 1 PH NVM List (761)
Chain-
Lin
k Name Default Range Description
761-293 PASS REGI SEN-
SOR 3(USED
TRAY
4)
0 None Measurement result: Register Sensor
O
FF
timing from the Registration Feed
(paper fed from Tray 4).
Theoretical value=Paper
lengt
h÷0.221
168mm/s (Normal
paper)
Theoretical value=Paper
lengt
h÷0.130mm
/s (This paper 1)
Unit=2ms/step (Normal paper)
Unit=3.3832ms/step (This paper 1)
Last storage location - see 761-370.
761-294 PASS REGI SEN-
SOR 4(USED
TRAY
4)
0 None Measurement result: Register Sensor
O
FF
timing from the Registration Feed
(paper fed from Tray 4).
Theoretical value=Paper
lengt
h÷0.221
168mm/s (Normal
paper)
Theoretical value=Paper
lengt
h÷0.130mm
/s (This paper 1)
Unit=2ms/step (Normal paper)
Unit=3.3832ms/step (This paper 1)
Last storage location - see 761-370.
761-295 PASS REGI SEN-
SOR 5(USED
TRAY
4)
0 None Measurement result: Register Sensor
O
FF
timing from the Registration Feed
(paper fed from Tray 4).
Theoretical value=Paper
lengt
h÷0.221
168mm/s (Normal
paper)
Theoretical value=Paper
lengt
h÷0.130mm
/s (This paper 1)
Unit=2ms/step (Normal paper)
Unit=3.3832ms/step (This paper 1)
Last storage location - see 761-370.
761-296 PASS REGI SEN-
SOR 6(USED
TRAY
4)
0 None Measurement result: Register Sensor
O
FF
timing from the Registration Feed
(paper fed from Tray 4).
Theoretical value=Paper
lengt
h÷0.221
168mm/s (Normal
paper)
Theoretical value=Paper
lengt
h÷0.130mm
/s (This paper 1)
Unit=2ms/step (Normal paper)
Unit=3.3832ms/step (This paper 1)
Last storage location - see 761-370.
Table 1 PH NVM List (761)