1/05
6-51
DocuColor 12/DCCS50
dC131PH NVM List (761)
General Procedures
Reissue
761-054 ADJUST PRE
FEED STOP POSI-
TION(TRAY 1
N
UDGER
ROLL)
0 0-31 Time from #1 Feed Out SNR ON to #1
Nudger Roll OFF
(PRE Feed stop position
- Adjustment)
Default=0ms
Range=0-62ms (0-31)
Unit=2ms/step
Default DATA=0 (2ms RTMR)
761-055 ADJUST PRE
F
EED
STOP POSI-
TION(TRAY 2
N
UDGER
ROLL)
0 0-39 Time from #2 Feed Out SNR ON to #2
Nudger Roll OFF
(PRE Feed stop position
- Adjustment)
Default=0ms
Range=0-78ms (0-39)
Unit=2ms/step
Default DATA=0 (2ms RTMR)
761-056 ADJUST PRE
F
EED
STOP POSI-
TION(TRAY 3
N
UDGER
ROLL)
0 0-39 Time from #2 Feed Out SNR ON to #2
Nudger Roll OFF
(PRE Feed stop position
- Adjustment)
Default=0ms
Range=0-78ms (0-39)
Unit=2ms/step
Default DATA=0 (2ms RTMR)
761-057 ADJUST PRE
F
EED
STOP POSI-
TION(TRAY 4
N
UDGER
ROLL)
0 0-39 Time from #2 Feed Out SNR ON to #2
Nudger Roll OFF
(PRE Feed stop position
- Adjustment)
Default=0ms
Range=0-78ms (0-39)
Unit=2ms/step
Default DATA=0 (2ms RTMR)
761-058 FUSER ENTRANS
SE
NSOR ON J
AM
TIMER SELECT
1 None Switches the Fuser Entrance Sensor On
J
am Timer
0:PM1
Non 0: PM2 or later
761-061 ADJUST INVERT
MOTO
R STOP
POSITION(FROM
FUSER EXIT SEN-
SOR OFF)
101 91-121 Time from Fuser Exit SNR OFF to Invert
Mot
or OFF (Exit Invert Point stop position
- Adjustment)
Default=202ms
Range=182.-242ms (91-121)
Unit=2.ms/step
761-062 INVERT MOTOR
ON TI
MI
NG(FACE
DOWN MODE)
55 40-70 Time from Invert Motor OFF to Invert
M
otor ON (Exit Invert Point stop time)
Default=110ms
Range=80-140ms (40-70)
Unit=2ms/step
Table 1 PH NVM List (761)
Chain-
Lin
k Name Default Range Description
761-063 INVERT MOTOR
OFF TIM-
ING(DUPLEX
MO
DE)
51 38-68 Ti
me from Invert Path SNR OFF to Invert
Motor O
FF (Duplex Invert Point stop posi-
tion - Adjustment)
Default=102ms
Range=76-136ms (38-68)
Unit=2ms/step
761-064 INVERT MOTOR
ON
TIM-
I
NG(DUPLEX
MODE
:PIT
CH
1200ms ONLY)
328 325-331 Time from Registration Motor ON using
Pit
ch
1200ms Duplex(*1) to Invert Motor
ON (Duplex inversion start timing)
Default=3280ms
Range=3250-3310ms (±30ms
) (
325-
331)
Unit=10ms/step
Default DATA=3280 (10ms RTMR)
(*1)LETL, A4L, B5L B/W, 4C MODE
761-065 INVERT MOTOR
ON TIM-
I
NG(DUPLEX
MODE
: PI
TCH
2400ms ONLY)
426 423-429 Time from Registration Motor ON using
Pitch
2400ms Duplex(*2) to Invert Motor
ON (Duplex inversion start timing)
Default=4260ms
Range=4230-4290ms (±30ms
) (
423-
429)
Unit=10ms/step
Default DATA=4260 (10ms RTMR)
(*2) B/W Mode except LETL, A4L, B5L
and B4S, and, 4C
Mode except LETL,
A4L and B5L
761-066 INVERT MOTOR
ON
TIM-
I
NG(DUPLEX
MODE
: PI
TCH
2083ms ONLY)
395 392-398 Time from Registration Motor ON using
Pitch 2083ms
Single Leaf Duplex(*3) to
Invert Motor ON (Duplex inversion start
timing)
Default=3950ms
Range=3920-3980ms (±30ms
) (
392-
398)
Unit=10ms/step
Default DATA=3950 (10ms RTMR)
(*3)B4S B/W MODE
Table 1 PH NVM List (761)
Chain-
Lin
k Name Default Range Description