1/05
6-53
DocuColor 12/DCCS50
dC131PH NVM List (761)
General Procedures
Reissue
761-104 ARRIVE AT TRAY 1
PRE FEED SEN-
SOR 4(USED
TR
AY
1)
0 None Measurement result: Timing from #1 Tray
Pre-Fe
ed start to #1 Pre-Feed SENSOR
ON
Theoretical value=115ms
JAM TIMER=408ms (50PPM,
12.
5PPM
B side) = 458ms (Other)
Unit=0.5ms/step (Normal paper)
Last storage location - see 761-351.
761-105 ARRIVE AT TRAY 1
PRE FE
ED SEN-
SOR 5(USED
TR
AY
1)
0 None Measurement result: Timing from #1 Tray
Pre-Fe
ed start to #1 Pre-Feed SENSOR
ON
Theoretical value=115ms
JAM TIMER=408ms (50PPM,
12.
5PPM
B side) = 458ms (Other)
Unit=0.5ms/step (Normal paper)
Last storage location - see 761-351.
761-106 ARRIVE AT TRAY 1
PRE FE
ED SEN-
SOR 6(USED
TR
AY
1)
0 None Measurement result: Timing from #1 Tray
Pre-Fe
ed start to #1 Pre-Feed SENSOR
ON
Theoretical value=115ms
JAM TIMER=408ms (50PPM,
12.
5PPM
B side) = 458ms (Other)
Unit=0.5ms/step (Normal paper)
Last storage location - see 761-351.
761-107 ARRIVE AT TRAY 1
PRE FE
ED SEN-
SOR 7(USED
TR
AY
1)
0 None Measurement result: Timing from #1 Tray
Pre-Fe
ed start to #1 Pre-Feed SENSOR
ON
Theoretical value=115ms
JAM TIMER=408ms (50PPM,
12.
5PPM
B side) = 458ms (Other)
Unit=0.5ms/step (Normal paper)
Last storage location - see 761-351.
761-108 ARRIVE AT TRAY 1
PRE FE
ED SEN-
SOR 8(USED
TR
AY
1)
0 None Measurement result: Timing from #1 Tray
Pre-Fe
ed start to #1 Pre-Feed SENSOR
ON
Theoretical value=115ms
JAM TIMER=408ms (50PPM,
12.
5PPM
B side) = 458ms (Other)
Unit=0.5ms/step (Normal paper)
Last storage location - see 761-351.
Table 1 PH NVM List (761)
Chain-
Lin
k Name Default Range Description
761-109 ARRIVE AT TRAY 1
PRE FEED SEN-
SOR 9(USED
TR
AY
1)
0 None Measurement result: Timing from #1 Tray
Pre-Fe
ed start to #1 Pre-Feed SENSOR
ON
Theoretical value=115ms
JAM TIMER=408ms (50PPM,
12.
5PPM B
side) = 458ms (Other)
Unit=0.5ms/step (Normal paper)
Last storage location - see 761-351.
761-110 ARRIVE AT TRAY 1
PRE FE
ED SEN-
SOR 10(USED
TR
AY
1)
0 None Measurement result: Timing from #1 Tray
Pre-Fe
ed start to #1 Pre-Feed SENSOR
ON
Theoretical value=115ms
JAM TIMER=408ms (50PPM,
12.
5PPM B
side) = 458ms (Other)
Unit=0.5ms/step (Normal paper)
Last storage location - see 761-351.
761-111 ARRIVE AT TRAY 2
PRE FE
ED SEN-
SOR 1(USED
TR
AY
2)
0 None Measurement result: Timing from #2 Tray
Pre-Fe
ed start to #2 Pre-Feed Sensor ON
Theoretical value=155ms
JAM TIMER=408ms (50PPM,
12.
5PPM B
side) = 458ms (Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/
step (Thick paper)
Last storage location - see 761-352.
761-112 ARRIVE AT TRAY 2
PRE FE
ED SEN-
SOR 2(USED
TR
AY
2)
0 None Measurement result: Timing from #2 Tray
Pre-Fe
ed start to #2 Pre-Feed Sensor ON
Theoretical value=155ms
JAM TIMER=408ms (50PPM,
12.
5PPM B
side) = 458ms (Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/
step (Thick paper)
Last storage location - see 761-352.
761-113 ARRIVE AT TRAY 2
PRE FE
ED SEN-
SOR 3(USED
TR
AY
2)
0 None Measurement result: Timing from #2 Tray
Pre-Fe
ed start to #2 Pre-Feed Sensor ON
Theoretical value=155ms
JAM TIMER=408ms (50PPM,
12.
5PPM B
side) = 458ms (Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/
step (Thick paper)
Last storage location - see 761-352.
Table 1 PH NVM List (761)
Ch
ain-
Lin
k Name Default Range Description

Table of Contents