1/05
6-75
DocuColor 12/DCCS50
dC131PH NVM List (761)
General Procedures
Reissue
761-312 PASS Machine
EXIT SENSOR 2
DSP: Pass Machine
E
xit S
NR 2
0 None Measurement result (Last 10): Machine
Exit
Sensor OFF timing from Fuser Exit
Sensor OFF.
Default=0ms
Range=None
Theoretical value=221ms (Straight
eject
ion)
, 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
761-313 PASS Machine
EX
IT SEN
SOR 3
0 None Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
eject
ion)
, 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
761-314 PASS Machine
EX
IT SEN
SOR 4
0 None Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
eject
ion)
, 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
761-315 PASS Machine
EX
IT SEN
SOR 5
0 None Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
eject
ion)
, 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
Table 1 PH NVM List (761)
Ch
ain-
Link Name Default Range Description
761-316 PASS Machine
EXIT SENSOR 6
0 None Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
eject
ion
), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
761-317 PASS Machine
EXI
T S
ENSOR 7
0 None Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
eject
ion
), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
761-318 PASS Machine
EXI
T S
ENSOR 8
0 None Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
eject
ion
), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
761-319 PASS Machine
EXI
T S
ENSOR 9
0 None Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
eject
ion
), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
761-320 PASS Machine
EXI
T S
ENSOR 10
0 None Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
eject
ion
), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
Table 1 PH NVM List (761)
Ch
ain-
Lin
k Name Default Range Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox DocuColor 12/DCCS50 and is the answer not in the manual?

Xerox DocuColor 12/DCCS50 Specifications

General IconGeneral
BrandXerox
ModelDocuColor 12/DCCS50
CategoryAll in One Printer
LanguageEnglish

Related product manuals