1/05
6-76
DocuColor 12/DCCS50
dC131PH NVM List (761)
Reissue
General Procedures
761-321 1PASS INVERT
PATH SENSOR 1
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
761-322 PASS INVERT
PATH S
ENSOR 2
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
761-323 PASS INVERT
PATH S
ENSOR 3
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
761-324 PASS INVERT
PATH S
ENSOR 4
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
761-325 PASS INVERT
PATH S
ENSOR 5
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
Table 1 PH NVM List (761)
Ch
ain-
Lin
k Name Default Range Description
761-326 PASS INVERT
PATH SENSOR 6
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
761-327 PASS INVERT
PAT
H SENSOR 7
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
761-328 PASS INVERT
PAT
H SENSOR 8
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
761-329 PASS INVERT
PAT
H SENSOR 9
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
761-330 PASS INVERT
PAT
H SENSOR 10
0 None Measurement result (Last 10): Invert Path
Sensor OFF timing from Fuser Exit Sen-
sor OFF.
Theoretical value=331ms
JAM TIMER=250-532ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-373.
Table 1 PH NVM List (761)