Page #757 background image
1/05
6-77
DocuColor 12/DCCS50
dC131PH NVM List (761)
General Procedures
Reissue
761-331 ARRIVE AT
DUPLEX PATH
SENSOR 1
0 None Measurement result (Last 10): Dup Path
Sens
or ON timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
761-332 ARRIVE AT
DU
PL
EX PATH
SENSOR 2
0 None Measurement result (Last 10): Dup Path
Sens
or ON timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
761-333 ARRIVE AT
DU
PL
EX PATH
SENSOR 3
0 None Measurement result (Last 10): Dup Path
Sens
or ON timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
761-334 ARRIVE AT
DU
PL
EX PATH
SENSOR 4
0 None Measurement result (Last 10): Dup Path
Sens
or ON timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
761-335 ARRIVE AT
DU
PL
EX PATH
SENSOR 5
DSP: ARRV DUP
P
ath
SNR 5
0 None Measurement result (Last 10): Dup Path
Sens
or O
N timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
761-336 ARRIVE AT
DU
PL
EX PATH
SENSOR 6
0 None Measurement result (Last 10): Dup Path
Sens
or ON timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
Table 1 PH NVM List (761)
Chain-
Lin
k Name Default Range Description
761-337 ARRIVE AT
DUPLEX PATH
SENSOR 7
0 None Measurement result (Last 10): Dup Path
Sens
or ON timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
761-338 ARRIVE AT
DUP
LEX
PATH
SENSOR 8
0 None Measurement result (Last 10): Dup Path
Sens
or ON timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
761-339 ARRIVE AT
DUP
LEX
PATH
SENSOR 9
0 None Measurement result (Last 10): Dup Path
Sens
or ON timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
761-340 ARRIVE AT
DUP
LEX
PATH
SENSOR 10
0 None Measurement result (Last 10): Dup Path
Sens
or ON timing from Dup In Sensor
ON.
Theoretical value=570ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-374.
761-341 ARRIVE AT
DUP
LEX
OUT
SENSOR 1
0 None Measurement result (Last 10): Duplex Out
Sens
or ON timing from Duplex Path Sen-
sor ON.
Theoretical value=808ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-375.
761-342 ARRIVE AT
DUP
LEX
OUT
SENSOR 2
0 None Measurement result (Last 10): Duplex Out
Sens
or ON timing from Duplex Path Sen-
sor ON.
Theoretical value=808ms
Unit=10ms/step
Default DATA=0 (10ms RTMR)
Last storage location - see 761-375.
Table 1 PH NVM List (761)
Chain-
Lin
k Name Default Range Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox DocuColor 12/DCCS50 and is the answer not in the manual?

Xerox DocuColor 12/DCCS50 Specifications

General IconGeneral
BrandXerox
ModelDocuColor 12/DCCS50
CategoryAll in One Printer
LanguageEnglish

Related product manuals