DocuColor 12/DCCS50
IQ 47 ATC Sensor RAP
Image Quality
Reissue
ATC SENSORS RESULT JUDGMENT OF TC (OK or NG, see step 4)
NVM COUNTER FOR TC MEASUREMENT FAILURE. (see Appendix 3c)
ATC SENSOR TC READING RESULTS. (see value range description detailed in step 8f).
Appendix 1. ATC set-up procedure
1. Install at least one new developer. The ATC Se
nsor must
be calibrated from new devel-
oper.
2. Set 775-731 to 1 turns ATC Sensor on. (0 = off).
3. Confirm NVM 773-266 through 269 are set to 230, 230, 250, 160. (ADC Targets nominal
values).
4. S
et 775-736 to 1. (Value will return to 0 after executing dC922).
5. Set 775-737 to appropriate value depending on develop
er material replaced for set-up.
1 = replacement of YMC
2 = replacement of Y
3 = replacement of M
4 = replacement of C
5 = replacement of YM
6 = replacement of YC
7 = replacement of MC
0~65535 Color Selection for ATC Con-
trol
1: YMC (initial value) 2: only
Y, 3:
only M, 4: only C, 5: only
YM, 6: only YC, 7: only MC
Table 5
Chain-Link
No
.
NVM
D
esignation
Initial
Value Set Range Meaning
775-741 TC_OFFSET_OU
T_
jd
1 0
~65535 Judgment of TCOFFSET out-
put (1: OK, 0:NG)
775-742 TC_Ref_OUT_jd 1 0~65535 Judgement of TC reference
plane measurem
ent (1: OK,
0:NG)
775-743 TC_OUT_jd[Y] 1 0~65535 Judgement of measured TC
v
al
ue (1: OK, 0:NG) [Y]
775-744 TC_OUT_jd[M] 1 0~65535 Judgement of measured TC
val
ue (1: OK, 0:NG) [M]
775-745 TC_OUT_jd[C] 1 0~65535 Judgement of measured TC
val
ue (1: OK, 0:NG) [C]
775-746 TC_Ref_OPEN_
OUT_jd
1 0~
65535 Judgement of measured TC
value with shutter open (1:
OK, 0:NG)
775-747 TC_SET_OUT_jd
[Y
]
1 0~
65535 Judgement of measured TC
value at Diag setup (1: OK,
0:NG) [Y]
775-748 TC_SET_OUT_jd
[M
]
1 0~
65535 Judgement of measured TC
value at Diag setup (1: OK,
0:NG) [M]
775-749 TC_SET_OUT_jd
[C]
1 0~65535 Judgement of measured TC
value at
Diag set
up (1: OK,
0:NG) [C]
775-750 TC_SET_ALL_jd 1 0~65535 General judgement of ATC
c
on
trol (1: OK, 0:NG)
Table 6
Chain-Link
No
.
NVM
D
esignation
Initial
Value Set Range Meaning
775-751 TC_OFFSET_OU
T_
Fai
l
0 0~65535 Frequency of TCOFFSET
output fail (hidden fail)
Table 4
Cha
in-Link
No.
NVM
Designation
Initial
Value Set Range Meaning
775-752 TC_Ref_OUT_Fai
l
0 0~65535 Frequency of measured TC
value fail with reference
plane (hidden fail)
775-753 TC_OUT_Fail[Y] 0 0~65535 Frequency of measured TC
value f
ail (hidden f
ail) [Y]
775-754 TC_OUT_Fail[M] 0 0~65535 Frequency of measured TC
value fail (hidden f
ail) [M]
775-755 TC_OUT_Fail[C] 0 0~65535 Frequency of measured TC
value fail (hidden f
ail) [C]
775-756 TC_Ref_OPEN_
OUT_F
ail
0 0~65535 Frequency of measured TC
value fail with shutter open
(hidden fail)
Table 7
Chain-Link
No
.
NVM
Designation
Initial
Value Set Range Meaning
775-791 TC_OUT_Adj[Y] 200 140 ~ 200 TC output adjustment value
[Y
]
775-792 TC_O
UT_Adj[M] 200 140 ~ 200 TC output adjustment value
[M]
775-793 TC_O
UT_Adj[C] 200 140 ~ 200 TC output adjustment value
[C]
775-782 TC_O
UT_Daig_A
dj
0 140 ~ 200 Adjustment results of TC
measured value at
Diag I/O
check
Table 6
Cha
in-Link
No.
NVM
Designation
Initial
Value Set Range Meaning