iNFiNiT! Family Operation Manual
Revision D 9-25 Advanced Playback
PAUSE TIME
EXCEEDS ROLL
TIME.
The total pause dura-
tion in the list is longer
than the duration speci-
fied for the Timed Roll.
Shorten the Pause
duration or increase the
Time duration of the
Timed Roll.
SPECIFIED TIME
TOO SHORT TO
ROLL.
The duration for a
Timed Roll is too short,
requiring that the Roll
exceeds the system’s
maximum Roll speed.
Lengthen the Time
duration.
SPECIAL ROLL
FOR ALL TIMED
ROLLS.
Timed Roll requires that
the
Special Roll com-
mand is also in the list.
You must enter the
Special Roll com-
mand before entering
the
Time command.
CHANNEL A AND B
MUST SPECIFY A
FRAME BUFFER.
There is a Special
Roll
command in the
list, but buffers have not
been specified for both
channels.
Enter the Mix Settings
window, and assign a
buffer to CHANNEL A
and a different buffer to
CHANNEL B. See
§16.7 for information on
channel and buffer
assignments.
Table 9-2: Roll Control Buffer Error Messages
(UURU0HVVDJH ([SODQDWLRQ )L[