one-way-hardware-timestamp;
probe-count count;
probe-interval seconds;
probe-type type;
routing-instance instance-name;
source-address address;
target (url url | address address);
test-interval interval;
thresholds thresholds;
traps traps;
}
}
NOTE: The ACX Series routers do not support the configuration of RPM
probes to a routing instance along with the configuration of the
hardware-timestamp statement.
NOTE: ACX5000 line of routers do not support hardware-timestamp feature
for RPM.
Related
Documentation
Configuring Real-Time Performance Monitoring•
• Examples: Configuring Real-Time Performance Monitoring
• show services rpm probe-results
TWAMP on ACX Series
The Two-Way Active Measurement Protocol (TWAMP) defines a standard for measuring
IP performance between two devices in a network. You can configure TWAMP on ACX
Series routers. ACX Series routers support only the reflector side of TWAMP.
For more information about TWAMP, see RFC 5357, A Two-Way Active Measurement
Protocol (TWAMP).
To configure TWAMP properties, include the twamp statement at the [edit services rpm]
hierarchy level:
[edit services rpm]
twamp {
server {
authentication-mode mode;
client-list list-name {
[ address address ];
authentication none];
}
max-connection-duration hours;
maximum-connections count;
maximum-connections-per-client count;
Copyright © 2017, Juniper Networks, Inc.964
ACX Series Universal Access Router Configuration Guide