relay (Chassis Alarm)
Syntax relay
input {
port port-number {
mode (close | open);
trigger (ignore | red | yellow);
}
}
output{
port port-number {
input-relay input-relay;
mode (close | open);
temperature;
}
}
Hierarchy Level [edit chassis alarm]
Release Information Statement introduced in Junos OS Release 12.3.
Description Configure input and output relay alarms.
The remaining statements are explained separately. See CLI Explorer.
Required Privilege
Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related
Documentation
User-Defined Alarm Relay Overview on page 158
show chassis craft-interface on page 1865
show chassis alarms on page 1845