halt-on-prefix-down (RFC 2544 Benchmarking)
Syntax halt-on-prefix-down;
Hierarchy Level [edit services rpm rfc2544-benchmarkingtests test-name test-name]
Release Information Statement introduced in Junos OS Release 12.3X53 for ACX Series routers.
Description By default, the RFC 2544-based benchmarking test ignores a prefix-down event (when
the prefix associated with the test goes down) and continues to run. If this parameter is
specified, a prefix that moves to the down state causes the corresponding tests to be
stopped. The show command output for the test displays that the test was aborted due
to the prefix going down.
Required Privilege
Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related
Documentation
RFC 2544-Based Benchmarking Tests Overview on page 1335
Configuring RFC 2544-Based Benchmarking Tests on page 1341
rfc2544-benchmarking on page 1698
1547Copyright © 2017, Juniper Networks, Inc.