maximum-paths
Syntax maximum-paths path-limit <log-interval seconds> <log-only | threshold value>;
Hierarchy Level [edit logical-systems logical-system-name routing-instances routing-instance-name
routing-options],
[edit logical-systems logical-system-name routing-options],
[edit routing-instances routing-instance-name routing-options],
[edit routing-options]
Release Information Statement introduced in Junos OS Release 8.0.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Statement introduced in Junos OS Release 11.3 for the QFX Series.
Statement introduced in Junos OS Release 14.1X53-D20 for the OCX Series.
Description Configure a limit for the number of routes installed in a routing table based upon the
route path.
NOTE: The maximum-paths statement is similar to the maximum-prefixes
statement. The maximum-prefixes statement limits the number of unique
destinations in a routing instance. For example, suppose a routing instance
has the following routes:
OSPF 10.10.10.0/24
ISIS 10.10.10.0/24
These are two routes, but only one destination (prefix). The maximum-paths
limit applies the total number of routes (two). The maximum-prefixes limit
applies to the total number of unique prefixes (one).
Options log-interval seconds—(Optional) Minimum time interval (in seconds) between log
messages.
Range: 5 through 86,400
log-only—(Optional) Sets the route limit as an advisory limit. An advisory limit triggers
only a warning, and additional routes are not rejected.
path-limit—Maximum number of routes. If this limit is reached, a warning is triggered and
additional routes are rejected.
Range: 1 through 4,294,967,295 (2
32
– 1)
Default: No default
threshold value—(Optional) Percentage of the maximum number of routes that starts
triggering a warning. You can configure a percentage of the path-limit value that
starts triggering the warnings.
Range: 1 through 100
Copyright © 2017, Juniper Networks, Inc.1606