clock-class-to-quality-level-mapping (ACX Series)
Syntax clock-class-to-quality-level-mapping {
quality-level quality-level;
}
Hierarchy Level [edit protocols ptp slave]
Release Information Statement introduced in Junos OS Release 12.1.
Statement introduced in Junos OS Release 12.2 for the ACX Series Universal Access
Routers.
Description Configure the destination node to override the default Precision Time Protocol clock
class to Ethernet Synchronization Message Channel (ESMC) mapping.
The remaining statement is explained separately. See CLI Explorer.
Required Privilege
Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Related
Documentation
• IEEE 1588v2 Precision Timing Protocol (PTP) on ACX Series Universal Access Routers
on page 237
• Precision Time Protocol Overview
Copyright © 2017, Juniper Networks, Inc.1462