Loading...
announce-interval (Master Clock)
Syntax announce-interval announce-interval-value;
Hierarchy Level [edit protocols ptp master]
Release Information Statement introduced in Junos OS Release 12.3 for ACX Series Routers.
Description Configure the logarithmic mean interval for the announce messages to be sent by the
master. This is a log
2
value, which means that announce messages are requested to be
sent every two seconds.
Options announce-interval-valueAnnounce interval value for announce messages.
Range: 0 through 4
Default: 1
Required Privilege
Level
routing—To view this statement in the configuration.
routing-controlTo add this statement to the configuration.
Related
Documentation
IEEE 1588v2 PTP Boundary Clock Overview on page 234
Configuring Precision Time Protocol Clocking on page 243
Configuring a PTP Master Boundary Clock on page 244
Example: Configuring a PTP Boundary Clock With Unicast Negotiation on page 250
Example: Configuring a PTP Boundary Clock on page 248
Copyright © 2017, Juniper Networks, Inc.1430