port (Alarm Relay Output)
Syntax port port-number {
input-relay input-relay;
mode (close | open);
temperature;
}
Hierarchy Level [edit chassis alarm relay output ]
Release Information Statement introduced in Junos OS Release 12.3.
Description Configure the output relay alarm port.
The remaining statements are explained separately. See CLI Explorer.
Options port-number—Output relay alarm port numbers are 0 through 3. However, only ports 0
and 1 are configurable. Output relay ports 2 and 3 are used to indicate system major
and minor alarms and are in normally open mode.
Required Privilege
Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related
Documentation
• User-Defined Alarm Relay Overview on page 158
• show chassis craft-interface on page 1865
• show chassis alarms on page 1845